Centurion™ Custom Control Panel For Sale

$0

Report problem
Processing your request, Please wait....
Centurion™ Custom Control Panel For Sale

Centurion™ Custom Control Panel For Sale

The Centurion™ Custom Control Panel is a fully integrated control and monitoring system for a variety of applications. Control Panels are designed on an engineered-to-order basis, and we can partner with you to create user customized, multi-application design for your specifications. We specialize in building panels for use in hazardous areas, and you can be assured that the design will include components and wiring methods to meet those standards. The Centurion C5 Controller in these panels is custom programmed for any variety of custom control loop algorithms, custom calculations, highly specialized valve sequencing or any other control scenario for your equipment. Applications for electric motor, electronic engine and mechanical engine-driven gas compressors and pumps are an example of the types of equipment that can be used with our Control Panel; however, the system lends itself to almost any control solution that you may have in mind.

The Application Firmware is developed in-house and tested fully by our quality control department. It can be updated in panels using USB memory storage devices or free PC-based transfer tools.

C5 Series Main I/O Module

Operating temperature: -40° to 185° F (-40° to 85° C)
Power input: 30 W max 10-30 VDC
Configuration: PC-based Centurion Configuration Software
Application firmware:
Centurion Custom option offers highly customized applications
Integrate with Rockwell Automation Processors as I/O module to write IEC 61131-3 logic (Ladder Logic, Structured Text, Function Block Diagram)
All I/O options individually software selectable: No jumpers required
Clock: Battery backed internal real-time clock, approximately 10 years unpowered service life
12 Analog inputs*:
0-24 mA or 0-5 VDC, 15-bit hardware
4 resistive potentiometer measurement
32 Digital inputs*:
NO or NC (active high/active low) intrinsically safe
Optically isolated DC digital inputs (active high/active low) with LED indicators
Polarity sense / wire fault detection on normally closed systems
Approved for use with general purpose switches in hazardous areas
Eight temperature inputs*:
J or K Type Thermocouples
3-wire 100Ω Pt RTD temperature inputs***
Open, short DC-, short DC+ wire fault detection
Cold junction compensation
One magnetic pickup input/AC run signal:
30 to 10 kHz, 4.5 VAC rms min, 120 VAC rms max
10 digital outputs:
LED indicators:
4 relay outputs, form C, dry contacts
4 FET outputs (source)
2 FET outputs (sink)
Four analog outputs:
4-20 mA, 16-bit hardware
11 Communication ports:
Two SERIAL RS232:
Protocol: MODBUS RTU (server)
Two SERIAL RS485:
Protocol: MODBUS RTU (server)
One USB: Host Type A (data log access, firmware updates)
One USB: Slave Type B (configuration / firmware updates)
Two CAN:
One proprietary for FW Murphy hardware
One reserved for J1939 Engine ECU
Two Ethernet 10/100 (DLR):
Protocol: Modbus TCP/IP (server)
EtherNet/IP (CIP)
One WiFi: Optional C5-1 only
Third-party approvals:
Class I, Div 2, Grps A, B, C, D Haz. Loc. T4
Class I, Zone 2, AEx ec [ic] nC IIC T4 Gc, Ex ec [ic] nC IIC T4 Gc X
ATEX Zone 2
II 3G Ex ec [ic] nC IIC T4 Gc
DEMKO 18 ATEX 1926X
-40°C < Tamb < +85°C
IECEx Zone 2
Ex ec [ic] nC IIC T4 Gc
IECEx UL 18.0072X
-40°C < Tamb < +85°C
MX4-R2 Expansion I/O Module

Operating Temperature: -40° to 185° F (-40° to 85° C)
Power input: 14.1 W max 10-30 VDC
18* thermocouple inputs: J or K Type thermocouples
9* 3-wire 100Ω Pt RTD temperature inputs***
Open, short DC-, Short DC+ wire fault detection
Cold junction compensation
One magnetic pickup input* / AC Run Signal: 4.5 VAC – 120 VAC, 30 Hz – 10 kHz
Third-party approvals:
Class I, Div 2, Grps A, B, C, D Haz. Loc. T4
Class I, Zone 2, AEx ec [ic] IIC T4 Gc, Ex ec [ic] IIC T4 Gc X
ATEX Zone 2
II 3G Ex ec [ic] IIC T4 Gc
DEMKO 18 ATEX 1926X
-40°C < Tamb < +85°C
IECEx Zone 2
Ex ec [ic] IIC T4 Gc
IECEx UL 18.0072X
-40°C < Tamb < +85°C
MX5-R2 Expansion I/O Module

Operating temperature: -40° to 185° F (-40° to 85° C)
Power input: 16.5 W max 10-30 VDC
24*Digital inputs:
NO or NC (active high/active low) instrincally safe
Optically isolated DC digital inputs (active high/active low) with LED indicators
Polarity sense / wire fault detection on normally closed systems
Approved for use with general purpose switches in hazardous areas
10* analog inputs: 0-24 mA or 0-5 VDC, 15 bit hardware
16* digital outputs: FET (sink)
4 analog outputs: 4-20 mA, 16 bit hardware
1 magnetic pickup input* /AC Run Signal: 4.5 VAC -120 VAC, 30 Hz to 10 kHz
Third-party approvals:
Class I, Div 2, Grps A, B, C, D Haz. Loc. T4
Class I, Zone 2, AEx ec [ic] IIC T4 Gc, Ex ec [ic] IIC T4 Gc X
ATEX Zone 2
II 3G Ex ec [ic] IIC T4 Gc
DEMKO 18 ATEX 1926X
-40°C < Tamb < +85°C
IECEx Zone 2
Ex ec [ic] IIC T4 Gc X
IECEx UL 18.0072X
-40°C < Tamb < +85°C
* Non-incendive (Digital Inputs, An