Centurion™ Configurable Control Panel For Sale
$0
Centurion™ Configurable Control Panel For Sale
The Centurion Configurable Control Panel is a fully integrated control and monitoring system for a variety of applications. Control Panels can be designed on an engineered-to-order basis, or we can partner with you to create standard, multi-application designs for your specifications. We specialize in building panels for use in hazardous areas, and you can be assured that the design will include components and wiring methods to meet those standards. The Centurion Controller can be configured for a variety of auto start/stop, various close loop controls for valves, louvers or speed actuation, and sequenced startup and shutdown operation for your equipment. Applications for electric motor, electronic engine and mechanical engine-driven gas compressors and pumps are an example of the types of equipment that can be used with our Control Panel. Changes to configurations can be done with simple Centurion Configuration Tool software, without the need for any programming language experience.
C5 Series Main I/O Module
Operating temperature: -40° to 185° F (-40° to 85° C)
Power input: 30 W max 10-30 VDC
Configuration: PC-based Centurion Configuration Software
Application firmware:
Standard offers a user-configurable experience
All I/O options individually software selectable: No jumpers required
Clock: Battery backed internal real-time clock, approximately 10 years unpowered service life
12 Analog inputs*:
0-24 mA or 0-5 VDC, 15-bit hardware
4 resistive potentiometer measurement
32 Digital inputs*:
NO or NC (active high/active low) intrinsically safe
Optically isolated DC digital inputs (active high/active low) with LED indicators
Polarity sense / wire fault detection on normally closed systems
Approved for use with general purpose switches in hazardous areas
Eight temperature inputs*:
J or K Type Thermocouples
3-wire 100Ω Pt RTD temperature inputs***
Open, short DC-, short DC+ wire fault detection
Cold junction compensation
One magnetic pickup input/AC run signal:
30 to 10 kHz, 4.5 VAC rms min, 120 VAC rms max
10 digital outputs:
LED indicators:
4 relay outputs, form C, dry contacts
4 FET outputs (source)
2 FET outputs (sink)
Four analog outputs:
4-20 mA, 16-bit hardware
11 Communication ports:
Two SERIAL RS232:
Protocol: MODBUS RTU (server)
Two SERIAL RS485:
Protocol: MODBUS RTU (server)
One USB: host Type A (data log access, firmware updates)
One USB: server Type B (configuration / firmware updates)
Two CAN:
One proprietary for FW Murphy hardware
One reserved for J1939 Engine ECU
Two Ethernet 10/100 (DLR):
Protocol: Modbus TCP/IP (server)
EtherNet/IP (CIP)
One WiFi: Optional C5-1 only
Third-party approvals:
Class I, Div 2, Grps A, B, C, D Haz. Loc. T4
Class I, Zone 2, AEx ec [ic] nC IIC T4 Gc, Ex ec [ic] nC IIC T4 Gc X
ATEX Zone 2
II 3G Ex ec [ic] nC IIC T4 Gc
DEMKO 18 ATEX 1926X
-40°C < Tamb < +85°C
IECEx Zone 2
Ex ec [ic] nC IIC T4 Gc
IECEx UL 18.0072X
-40°C < Tamb < +85°C
MX4-R2 Expansion I/O Module
Operating Temperature: -40° to 185° F (-40° to 85° C)
Power input: 14.1 W max 10-30 VDC
Configuration: PC-based Centurion Configuration Software
18* thermocouple inputs: J or K Type thermocouples
9* 3-wire 100Ω Pt RTD temperature inputs***
Open, short DC-, Short DC+ wire fault detection
Cold junction compensation
One magnetic pickup input* / AC Run Signal: 4.5 VAC – 120 VAC, 30 Hz – 10 kHz
Third-party approvals:
Class I, Div 2, Grps A, B, C, D Haz. Loc. T4
Class I, Zone 2, AEx ec [ic] IIC T4 Gc, Ex ec [ic] IIC T4 Gc X
ATEX Zone 2
II 3G Ex ec [ic] IIC T4 Gc
DEMKO 18 ATEX 1926X
-40°C < Tamb < +85°C
IECEx Zone 2
Ex ec [ic] IIC T4 Gc
IECEx UL 18.0072X
-40°C < Tamb < +85°C
MX5-R2 Expansion I/O Module
Operating temperature: -40° to 185° F (-40° to 85° C)
Power input: 16.5 W max 10-30 VDC
Configuration: PC-based Centurion Configuration Software
10* analog inputs: 0-24 mA or 0-5 VDC, 15 bit hardware
6 digital outputs: FET (sink)
4 analog outputs: 4-20 mA, 16 bit hardware
1 magnetic pickup input* /AC Run Signal: 4.5 VAC -120 VAC, 30 Hz to 10 kHz
Third-party approvals:
Class I, Div 2, Grps A, B, C, D Haz. Loc. T4
Class I, Zone 2, AEx ec [ic] IIC T4 Gc, Ex ec [ic] IIC T4 Gc X
ATEX Zone 2
II 3G Ex ec [ic] IIC T4 Gc
DEMKO 18 ATEX 1926X
-40°C < Tamb < +85°C
IECEx Zone 2
Ex ec [ic] IIC T4 Gc X
IECEx UL 18.0072X
-40°C < Tamb < +85°C
* Non-incendive (Digital Inputs, Analog Inputs and Temperature Inputs are intrinsically safe and non-incendive).
*** RTD=Resistive Temperature Device, American RTD Standard, TCR 0.00392, units Ohms/Ohm / deg. between 0-100 C.
M-VIEW Monochrome Display MV-5-C
Operating temperature: -40° to 185° F (-40° to 85° C)
Power input: 11 W max 10-30 VDC
Screen: 320 x 240 pixels, LCD display with backlight
User interface: 12-key keypad set point entry, alarm acknowledgment, start, stop, reset, etc.
Communicat
State/Province | Texas |
Country | United Kingdom |
Quantity | 1 |
Allow Deals | Yes |
I Want To | Sell |
NotesThe Centurion™ Configurable Controller (C5 Series) is a hybrid of annunciator and compressor controller. The C5 combines the monitoring and shutdown features of an annunciator, with auto-start and basic engine controls that help prevent shutdowns. |